Floor Standing AC 10HP Installation Kit
Original price was: ₦123,760.00.₦122,300.00Current price is: ₦122,300.00.
Floor Standing AC 10HP Installation Kit typically refers to the components required for installing a 10 horsepower (HP) floor-standing air conditioning unit. A 10HP AC unit is generally used for larger spaces, such as commercial buildings, warehouses, offices, or other industrial settings, where higher cooling capacity is needed.
- Description
- Additional information
- Reviews (0)
Description
Indoor Unit (Floor Standing AC Unit)
- The floor-standing air conditioner is typically a large unit placed on the floor to cool a room or larger area.
- It includes a fan, evaporator coil, and other components necessary to cool and dehumidify the air.
2. Outdoor Unit (Condenser Unit)
- The outdoor unit houses the compressor, condenser coil, and fan. The indoor and outdoor units are connected by refrigerant piping.
- This unit is placed outside the building, typically on the ground or mounted on the wall (depending on the system type).
3. Refrigerant Piping and Insulation
- Copper Refrigerant Pipes: Typically, copper pipes are used to connect the indoor and outdoor units. These pipes carry the refrigerant (usually R-22 or R-410A) between the units.
- Size: The size of the refrigerant pipes for a 10HP system is usually 1/2 inch or 5/8 inch for liquid and suction lines, but this can vary.
- Insulation: The copper pipes need to be insulated to prevent energy losses and condensation.
4. Electrical Wiring and Connection
- Power Cable: A heavy-duty electrical cable to connect the AC to the power supply. This includes cables for the indoor unit, outdoor unit, and any controllers.
- Circuit Breaker: The installation kit will likely include an appropriate circuit breaker or fuse for safety, protecting the system from electrical surges or overloads.
- Terminal Block: To connect the wiring from the units to the power supply.
- Control Wiring: Wires to connect the thermostat or controller to the system for regulating temperature and operation.
5. Drainage Pipe (Condensate Drain)
- The floor-standing AC will generate condensation during the cooling process, which must be drained out of the unit.
- A PVC or flexible drainage pipe is included to carry away the condensation from the indoor unit to the outside or drainage system.
- The drainage pipe needs to be properly installed to ensure that it is sloped to prevent water accumulation.
6. Mounting Brackets (for Outdoor Unit)
- Mounting brackets or supports are included for securing the outdoor condenser unit to the ground or wall. These brackets ensure stability and allow airflow around the condenser unit.
7. Isolation Pads (for Outdoor Unit)
- Vibration isolation pads are often used under the outdoor condenser unit to reduce vibrations and noise transmission into the building structure.
8. Filter and Protection Components
- Filters: These can include air filters for the indoor unit (to filter dust, dirt, and particles from the air) and any necessary filters for the system’s refrigerant lines.
- Fuses and Protection Covers: These are included to ensure the system runs safely and efficiently.
9. Control/Remote Panel
- Wired or wireless remote controllers or wall-mounted thermostats are often provided for controlling the air conditioner’s functions, including temperature, fan speed, and modes of operation (cooling, heating, dehumidification, etc.).
10. Vibration Isolation Mounts
- Vibration dampers or mounts may be included to reduce noise and vibration caused by the compressor unit, especially in large systems like a 10HP.
Installation Steps for a 10HP Floor Standing AC (Basic Outline):
-
Site Selection:
- Choose a location for the indoor unit that ensures effective airflow and cooling for the area.
- Select a suitable location for the outdoor unit, ensuring it has sufficient ventilation and is stable.
-
Mounting the Indoor Unit:
- Secure the indoor unit to the floor, typically using the floor mounting brackets included in the kit.
- Make sure there’s adequate space for airflow and access for maintenance.
-
Refrigerant Piping:
- Install the copper refrigerant piping between the indoor and outdoor units. Proper insulation should be applied to the pipes to avoid energy loss and prevent condensation.
-
Electrical Wiring:
- Connect the power cable from the AC to the electrical supply, making sure the correct circuit breaker is installed for safety.
- Connect any control wiring or thermostats to enable control over the system’s temperature.
-
Drainage System:
- Install the condensate drain pipe to carry water away from the indoor unit. Ensure the pipe has a slight slope for effective drainage.
-
Mounting the Outdoor Unit:
- Secure the outdoor unit to its foundation using mounting brackets. Ensure the unit is placed in a well-ventilated area and is level.
-
Testing and Commissioning:
- After completing the installation, test the system by turning on the AC and checking the cooling performance.
- Ensure there are no refrigerant leaks and that all components are functioning correctly.
-
Maintenance and Cleaning:
- Regular maintenance includes cleaning the filters, checking refrigerant levels, inspecting the drainage system, and ensuring the outdoor unit remains free of debris.
Typical Contents of a 10HP AC Installation Kit:
- Refrigerant Copper Pipes (Liquid & Suction lines)
- PVC Drain Pipe (for condensate water)
- Mounting Brackets (for outdoor unit)
- Electrical Cable and Terminal Block
- Vibration Isolation Pads (for outdoor unit)
- Air Filters (for indoor unit)
- Power Circuit Breaker (for electrical protection)
- Control Wiring and Remote Control
- User Manual and Installation Instructions
Important Considerations:
- Professional Installation: Due to the size and complexity of a 10HP AC system, it’s generally recommended to have the installation carried out by a professional HVAC technician to ensure proper handling of refrigerant, electrical connections, and to comply with local regulations.
- Regulations: Check local building codes and regulations for the installation of large AC units. You may require permits for refrigerant handling, electrical work, or unit placement.
Additional information
Weight | 20 kg |
---|---|
Dimensions | 19 × 12 × 15 cm |
Reviews
There are no reviews yet.